|
|
- Inductive Sensor
- Capacitive sensors
- Magnetic sensors
- Cylinder sensors
- Photo sensors
- Photoelectric fork sensors
- Laser sensors
- Fibre optic sensors
- Feedback systems
- Flow sensors
- Encoders
- Speed sensors
- Inclination sensors
- Pulse evaluation systems
- Vision sensors
- 3D sensors
- Systems for mobile
- Illumination
- Fail-safe inductive sensors
- Safety light curtains
- Safety light grids
- Safety relays
- Safety controllers
- AS-Interface
|
S1: flow monitoring S2: temperature monitoring Setting range: 3...300 cm/s (liquids) Application Application liquids and gases Medium temperature [°C] -25...80 Flow sensors Flow monitor Compact type for adapter Process connection: internal thread M18 x 1.5 for adapter Probe length: 45 mm 2 switching outputs S1: flow monitoring S2: temperature monitoring Setting range: 3...300 cm/s (liquids) Application Application liquids and gases Medium temperature [°C] -25...80 Electrical data Electrical design DC PNP Operating voltage [V] 19...36 DC Current consumption [mA] < 60 Protection class III Reverse polarity protection yes Outputs Output function 2 x normally open / closed programmable Current rating [mA] 2 x 250 Voltage drop [V] < 2.5 Short-circuit protection pulsed Overload protection yes Measuring / setting range Liquids Setting range [cm/s] 3...300 Greatest sensitivity [cm/s] 3...100 Gases Setting range [cm/s] 200...3000 Greatest sensitivity [cm/s] 200...800 Temperature monitoring Setting range [°C] 2...80 Accuracy / deviations Switch point accuracy [cm/s] ± 2...± 10 *) Hysteresis [cm/s] 2...5 *) Repeatability [cm/s] 1...5 *) Temperature drift [cm/s x 1/K] 0.1 **) Max. temperature gradient of medium [K/min] 300 Temperature monitoring Switch point accuracy [K] ± 3 (v > 5cm/s) ***) Hysteresis [K] 2 Repeatability [K] ± 2 Response time temperature (typ.) [s] 5 Resolution [K] 1 Reaction times Power-on delay time [s] 10 Response time [s] 1...10 Software / programming Adjustment of the switch point pushbuttons Environment Pressure rating [bar] 300 Ambient temperature [°C] -25...80 Storage temperature [°C] -25...100 Protection IP 67 Tests / approvals EMC EN 61000-4-2 ESD: 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated: 10 V/m EN 61000-4-4 Burst: 2 kV EN 61000-4-6 HF conducted: 10 V Shock resistance DIN IEC 68-2-27: 50 g (11 ms) Vibration resistance DIN EN 60068-2-6: 20 g (55...2000 Hz) MTTF [Years] 277 Mechanical data Process connection internal thread M18 x 1.5 for adapter Materials (wetted parts) stainless steel 316L / 1.4404; O-ring: FKM 8 x 1.5 gr 80° Shore A Housing materials stainless steel 316L / 1.4404; stainless steel / 301 / 1.4310; PC (Makrolon); PBT-GF 20; EPDM/X (Santoprene) Probe length L [mm] 45 Weight [kg] 0.256 Displays / operating elements Function display LED 10 LEDs, three-colour Electrical connection Connection M12 connector
»
Flow sensors - SF220A: 0 VND (SF220A | SFR14ABB/US/2G)
» Flow sensors - SF121A: 0 VND (SF121A | SFM12ABB/2G /6M) » Flow sensors - SI0557: 0 VND (SI0557 | SID10ADBFPKG/US-100) » Flow sensors - SI0556 : 0 VND (SI0556 | SID10ADBFPKG/US) » Flow sensors - SI0553 : 0 VND (SI0553 | SID10ADHFPKG/US-100) » Flow sensors - SI5006: 0 VND (SI5006 | SID10ADBFKOW/LS-100-IRF) » Flow sensors - SI5001: 0 VND (SI5001 | SID10ABBFNKG/US-100) |
Tel: (08) - 6675.2925 (08) - 3511.5746 Fax: (08) - 3511.7931 Hot Line: 0978.996.122
|
TRUONG THANH INDUSTRIAL CO., LTD.
29-31 Dinh Bo Linh Street, Ward 24, Binh Thanh District.
Telephone: 08-6675.2925 Fax: 08-3511.7931
Email: kd2@cntruongthanh.com
Hotline: 0978.996.122
29-31 Dinh Bo Linh Street, Ward 24, Binh Thanh District.
Telephone: 08-6675.2925 Fax: 08-3511.7931
Email: kd2@cntruongthanh.com
Hotline: 0978.996.122
Copyright © 2010 cntruongthanh.com
Phát triển bởi N N H