Control category 4 according to EN954-1 and IEC 61508 / SIL 3 For connection of an electro-sensitive protective equipment (ESPE) type 4 to EN 61496-1 Complies with the requirements: EN ISO 13849-1: category 4 PL e IEC 61508: SIL 3 Electrical data Electrical design 2 safe inputs (OSSD) Operating voltage [V] 26.5...31.6 DC Bus system AS-Interface Safe active AS-i module Connection via M12x1 sockets or cage clamps Control category 4 according to EN954-1 and IEC 61508 / SIL 3 For connection of an electro-sensitive protective equipment (ESPE) type 4 to EN 61496-1 Complies with the requirements: EN ISO 13849-1: category 4 PL e IEC 61508: SIL 3 Electrical data Electrical design 2 safe inputs (OSSD) Operating voltage [V] 26.5...31.6 DC Current consumption [mA] < 35 Rated insulation voltage [V] 40 Pulse withstand voltage [kV] 0.5 Max. switch-off voltage [V] 24 DC Overvoltage category II Electrical separation AS-interface - inputs (U AUX) safe separation to IEC 61203: 40 V DC Electrical separation AS-Interface - functional earth basic insulation to IEC 61203: 40 V DC Electrical separation inputs - functional earth (U AUX) basic insulation to IEC 61203: 350 V DC Protection class III Inputs Digital Circuit DC PNP Sensor supply ext. 24 V DC PELV^ Voltage range [V] 20.4...28.8 DC Max. current load for all inputs total [mA] < 2000 Input current High/Low [mA] 6…10 / 0…2 Switching level High / Low [V] > 11 / < 5 Short-circuit proof yes Overload protection yes Environment Ambient temperature [°C] -25...55 Storage temperature [°C] -25...85 Max. relative air humidity [%] 95 Protection IP 67 Tests / approvals EMC EN 50295 IEC 62026-2 Safety classification Mission time TM [h] 87600, (10 years), calculation basis: ambient temperature 40° C Safety-related reliability PFHd [1/h] 1.54E-09 MTTFd [Years] 1500 DC/CCF/Cat. 99.4 % / - / - Internal capacitance [nF] < 10 AS-i classification AS-i version 2.11 / 3.0 Extended addressing mode possible no AS-i profile S-0.B.E I/O configuration [hex] 0 ID code [Hex] B.E AS-i certificate 80002 Max. number of safety modules per master 31 Mechanical data Cable length between module and electro-sensitive protective equipment [m] < 10 Housing materials PA 6 Weight [kg] 0.28 Displays / operating elements Operation LED green Error LED Red Function display LED yellow
»
AS-Interface - AC001S : 0 VND (AC001S )
» AS-Interface - AC002S: 0 VND (AC002S) » AS-Interface - AC003S: 0 VND (AC003S) » AS-Interface - AC004S: 0 VND (AC004S) » AS-Interface - AC031S: 0 VND (AC031S) » AS-Interface - AC032S: 0 VND (AC032S) » AS-Interface - AC041S: 0 VND (AC041S ) |
Tel: (08) - 6675.2925 (08) - 3511.5746 Fax: (08) - 3511.7931 Hot Line: 0978.996.122
|
TRUONG THANH INDUSTRIAL CO., LTD.
29-31 Dinh Bo Linh Street, Ward 24, Binh Thanh District.
Telephone: 08-6675.2925 Fax: 08-3511.7931
Email: kd2@cntruongthanh.com
Hotline: 0978.996.122
29-31 Dinh Bo Linh Street, Ward 24, Binh Thanh District.
Telephone: 08-6675.2925 Fax: 08-3511.7931
Email: kd2@cntruongthanh.com
Hotline: 0978.996.122
Copyright © 2010 cntruongthanh.com
Phát triển bởi N N H