- Inductive Sensor
- Capacitive sensors
- Magnetic sensors
- Cylinder sensors
- Photo sensors
- Photoelectric fork sensors
- Laser sensors
- Fibre optic sensors
- Feedback systems
- Flow sensors
- Encoders
- Speed sensors
- Inclination sensors
- Pulse evaluation systems
- Vision sensors
- 3D sensors
- Systems for mobile
- Illumination
- Fail-safe inductive sensors
- Safety light curtains
- Safety light grids
- Safety relays
- Safety controllers
- AS-Interface
|
Electrical design DC PNP Operating voltage [V] 24 DC (19.2...30 DC) Rated insulation voltage [V] 30 Current consumption [mA] < 30 Protection class III Reverse polarity protection yes Power-on delay time [s] 5 Outputs Output function 2 x OSSD (A1 and A2) Output voltage at 24 V compatible with EN 61131-2 inputs Inductive sensors Fail-safe inductive sensor Metal thread M30 x 1.5 M12 connector Enable zone 6...12 mm; [nf] non-flush mountable Complies with the requirements: EN ISO 13849-1: 2008 category 4 PL e IEC 61508: SIL 3 IEC 62061: SILcl 3 Application Type of operation continuous operation (maintenance-free) Electrical data Electrical design DC PNP Operating voltage [V] 24 DC (19.2...30 DC) Rated insulation voltage [V] 30 Current consumption [mA] < 30 Protection class III Reverse polarity protection yes Power-on delay time [s] 5 Outputs Output function 2 x OSSD (A1 and A2) Output voltage at 24 V compatible with EN 61131-2 inputs type 1, 2, 3 Voltage drop [V] < 2.5; (100 mA) Current rating [mA] 100 Short-circuit protection yes Range Enable zone [mm] 6...12 Safe switching off distance s(ar) [mm] 30 Reaction times Response time to safety request [ms] ≤ 50 Response time when approaching the enable zone (enable time) [ms] ≤ 200 Risk time (response time for safety-related faults) [ms] ≤ 100 Environment Applications Class C to EN 60654-1 weatherproof application Ambient temperature [°C] -25...70, for service life ≤ 87600 h 10...40, for service life ≤ 175200 h Rate of temperature change [K/min] 0.5 Max. relative air humidity [%] 5...95, briefly 5...70, permanently Air pressure [kPa] 80...106 Height above sea level [m] ≤ 2000 Ionising radiation not permissible Salt spray no Protection IP 68 / IP 69K Tests / approvals EMC IEC 60947-5-2 Shock resistance IEC 60947-5-2 Vibration resistance IEC 60947-5-2 Safety classification Mission time TM [h] ≤ 175200, (20 years) Safety-related reliability PFHd [1/h] 2.5E-09 MTTFd [Years] 1992 DC/CCF/Cat. 99 % / 100 % / 4 Mechanical data Mounting non-flush mountable Housing materials stainless steel 316L / 1.4404; PBT Weight [kg] 0.255 Displays / operating elements Display LED yellow (signal), LED green (power) Electrical connection Connection M12 connector; Gold-plated contacts
»
Fail-safe inductive sensors - GM705S: 0 VND (GM705S | GIMC-4045-US/2OSSD)
» Fail-safe inductive sensors - GF711S : 0 VND (GF711S | GIFA4004-2PS/SIL2/V4A/US) » Fail-safe inductive sensors - GG712S: 0 VND (GG712S | GIGA4005-2PS/SIL2/US) » Fail-safe inductive sensors - GG711S: 0 VND (GG711S | GIGA4008-2PS/SIL2/V4A/US) » Fail-safe inductive sensors - GG851S: 0 VND (GG851S | GIGA4005B2PO/SIL2/US) » Fail-safe inductive sensors - GG505S: 0 VND (GG505S | GIGA-4015-US /V4A) » Fail-safe inductive sensors - GG507S: 0 VND (GG507S | GIGA-4010-US) |
Tel: (08) - 6675.2925 (08) - 3511.5746 Fax: (08) - 3511.7931 Hot Line: 0978.996.122
|
TRUONG THANH INDUSTRIAL CO., LTD.
29-31 Dinh Bo Linh Street, Ward 24, Binh Thanh District.
Telephone: 08-6675.2925 Fax: 08-3511.7931
Email: kd2@cntruongthanh.com
Hotline: 0978.996.122
29-31 Dinh Bo Linh Street, Ward 24, Binh Thanh District.
Telephone: 08-6675.2925 Fax: 08-3511.7931
Email: kd2@cntruongthanh.com
Hotline: 0978.996.122
Copyright © 2010 cntruongthanh.com