|
|
- Inductive Sensor
- Capacitive sensors
- Magnetic sensors
- Cylinder sensors
- Photo sensors
- Photoelectric fork sensors
- Laser sensors
- Fibre optic sensors
- Feedback systems
- Flow sensors
- Encoders
- Speed sensors
- Inclination sensors
- Pulse evaluation systems
- Vision sensors
- 3D sensors
- Systems for mobile
- Illumination
- Fail-safe inductive sensors
- Safety light curtains
- Safety light grids
- Safety relays
- Safety controllers
- AS-Interface
|
MONITOR FR-1N Housing for DIN rail mounting NAMUR input with wire monitoring 2 relay outputs 2 transistor outputs Analogue output 0/4...20 mA programmable Test function without external frequency Key function Application Application single pulse evaluation system with µprocessor for frequency; rotational speed; speed and machine cycles Switching function 2 switch points for monitoring overspeed/underspeed and acceptable range Electrical data Nominal voltage [V] 110...240 AC (50...60 Hz) / 27 DC (typ. 24 DC) Voltage tolerance [%] -20...+10 Power consumption [VA] 5 (3 W) Inputs Inputs NAMUR (EN 50227) auxiliary supply: typ. 8.2 V DC; short-circuit protected wire monitoring: < 0.1 mA / > 6.0 mA input frequency (max): 5 kHz (corresponds to min. pulse length / space 0.1 ms) Outputs Relay Contact rating 6 A (250 V AC); B300, R300 Transistor Transistor outputs pnp; external supply switching voltage/current: 24 V DC / max. 15 mA; short-circuit protected analogue Analogue output 0/4...20 mA Max. load [Ω] 500 limitation: 20.5 mA; accuracy: 1 % (of the final value) Measuring / setting range Setting range [pulses/min.] 1...60000 (0.1...1000 Hz) Accuracy / deviations Measuring error [% of the final value] < 1 Environment Ambient temperature [°C] -40...60 Storage temperature [°C] -40...85 Max. relative air humidity [%] 80 (31°C), linearly decreasing to 50 % (40 °C) Protection housing / terminals IP 50 / IP 20 Tests / approvals EMC EN 61010 2011 EMC 89/336/EEC EN 61000-6-2 2005 EN 61000-6-4 2007 Mechanical data Housing materials plastics Weight [kg] 0.381 Displays / operating elements Input pulses LED yellow (input pulses); red (wire fault) Output status indication LED green (lights when the relay is energised / the transistor is closed) Display OLED display 128 x 64 dots luminous Electrical connection Connection dual-chamber terminals 2 x 2.5 mm² (2 x AWG 14)
»
Pulse evaluation systems - DS2603: 0 VND (DS2603 | MONITOR/FS-1N/110-240VAC/DC)
» Pulse evaluation systems - DA0001: 0 VND (DA0001 | A300/230VAC) » Pulse evaluation systems - DT0001: 0 VND (DT0001 | T700/230VAC) » Pulse evaluation systems - DD2103: 0 VND (DD2103 | MONITOR/FR-1N/110-240VAC/DC) » Pulse evaluation systems - DD2003: 0 VND (DD2003 | MONITOR/FR-1 /110-240VAC/DC) » Pulse evaluation systems - DD2001: 0 VND (DD2001 | MONITOR/FR-1 /230VAC) » Pulse evaluation systems - DD2104: 0 VND (DD2104 | MONITOR/FR-1N/ 23-60VAC/DC) |
Tel: (08) - 6675.2925 (08) - 3511.5746 Fax: (08) - 3511.7931 Hot Line: 0978.996.122
|
TRUONG THANH INDUSTRIAL CO., LTD.
29-31 Dinh Bo Linh Street, Ward 24, Binh Thanh District.
Telephone: 08-6675.2925 Fax: 08-3511.7931
Email: kd2@cntruongthanh.com
Hotline: 0978.996.122
29-31 Dinh Bo Linh Street, Ward 24, Binh Thanh District.
Telephone: 08-6675.2925 Fax: 08-3511.7931
Email: kd2@cntruongthanh.com
Hotline: 0978.996.122
Copyright © 2010 cntruongthanh.com
Phát triển bởi N N H
