|
|
- Inductive Sensor
- Capacitive sensors
- Magnetic sensors
- Cylinder sensors
- Photo sensors
- Photoelectric fork sensors
- Laser sensors
- Fibre optic sensors
- Feedback systems
- Flow sensors
- Encoders
- Speed sensors
- Inclination sensors
- Pulse evaluation systems
- Vision sensors
- 3D sensors
- Systems for mobile
- Illumination
- Fail-safe inductive sensors
- Safety light curtains
- Safety light grids
- Safety relays
- Safety controllers
- AS-Interface
|
for 2 pnp switching sensors Diagnostic and fault output Adjustable frequency range 0.5...990 Hz / speed range 1...49500 rpm Complies with the requirements: EN ISO 13849-1: category 4 PL e IEC 61508: SIL 3 Application Application Monitoring of rotational or linear movements for adherence to a maximum setpoint (overspeed) Electrical data Electrical design Relay Operating voltage [V] 19.2...28.8 DC; incl. 5 % residual ripple Product characteristics Safety speed monitor Evaluation system for safe speed monitoring for 2 pnp switching sensors Diagnostic and fault output Adjustable frequency range 0.5...990 Hz / speed range 1...49500 rpm Complies with the requirements: EN ISO 13849-1: category 4 PL e IEC 61508: SIL 3 Application Application Monitoring of rotational or linear movements for adherence to a maximum setpoint (overspeed) Electrical data Electrical design Relay Operating voltage [V] 19.2...28.8 DC; incl. 5 % residual ripple Nominal voltage [V] 24 DC Current consumption [mA] ≤ 125 Protection class II Power-on delay time [ms] ≤ 3000 Sensor supply 24 V DC / ≤ 70 mA Inputs Input characteristics Pulse inputs S34, S43: "1": 6 mA / 24 V DC Adjustable speed range [rpm] 1...49500 Adjustable frequency range [Hz] 0.5...990 Input frequency [Hz] ≤ 2000 Outputs Output function 2 safety-related switching outputs (floating contacts) 1 fault output "Fault" (positive switching) 1 diagnostic output "Overspeed" (positive switching) Output data Fault output "Fault" Y7 and diagnostic output "Overspeed" Y8 ≤ 20 mA, 24 V DC, voltage drop ≤ 2 V DC, short-circuit proof, non safe Contact rating 6 A, 250 V AC / 24 V DC (≥ 6 mA); ohmic resistance Short-circuit protection The contacts are to be protected by means of fuses with a nominal current of < 3.6 A. Switching function Switching outputs 13-14 and 23-24 open if input frequency/speed above switch point Transistor output "Fault" Y7 open (LOW) in case of device fault or external fault Transistor output "Overspeed" Y8 open (LOW) when the switching outputs 13-14 and 23-24 are opened. Accuracy / deviations Hysteresis [%] 5 Reaction times Risk time (response time for safety-related faults) [ms] 5.5 Response time [ms] [fsel ≥ 30 Hz]: t = 8.5 + 400 x (fsel ÷ fin) [fsel < 30 Hz]: t = 8.5 + (4500 ÷ fin) Environment Ambient temperature [°C] -40...55, observe the free space for convection (see operating instructions) Storage temperature [°C] -40...75 Height above sea level [m] ≤ 2000 Relative humidity [%] 10...95 Protection IP 20 Safety classification Mission time TM [h] ≤ 175200, (20 years) Safety-related reliability PFHd [1/h] 7.69E-09 MTTFd [Years] 528.73 DC/CCF/Cat. 99.0 % Mechanical data Housing materials PA (polyamide) Installation rail TH35 (to EN 60715) Weight [kg] 0.3
»
Safety relays - DA101S: 0 VND (DA101S)
» Safety relays - G1501S: 0 VND (G1501S) » Safety relays - G1503S: 0 VND (G1503S) » Safety relays - AC016S: 0 VND (AC016S | CL90,Evaluation unit,AS-i) » Safety relays - AC1154: 0 VND (Addressing unit AS-i 3.0) » Safety relays - AC1212: 0 VND ( PowerSupply 230VAC 2x4A) » Safety relays - AC5230: 0 VND (ClassicLine 1AI C 1AO C 2DI) |
Tel: (08) - 6675.2925 (08) - 3511.5746 Fax: (08) - 3511.7931 Hot Line: 0978.996.122
|
TRUONG THANH INDUSTRIAL CO., LTD.
29-31 Dinh Bo Linh Street, Ward 24, Binh Thanh District.
Telephone: 08-6675.2925 Fax: 08-3511.7931
Email: kd2@cntruongthanh.com
Hotline: 0978.996.122
29-31 Dinh Bo Linh Street, Ward 24, Binh Thanh District.
Telephone: 08-6675.2925 Fax: 08-3511.7931
Email: kd2@cntruongthanh.com
Hotline: 0978.996.122
Copyright © 2010 cntruongthanh.com
Phát triển bởi N N H
