Sockets M12 x 1 Safe AS-i input module 4SI / 2DO T / 2LO Addressing socket Three orientations of the flat cable are possible Complies with the requirements: EN ISO 13849-1: PL d IEC 62061: SILcl 2 Electrical data Electrical design 2x2 safe inputs / 2 non-safe LED outputs / 2 non-safe outputs Operating voltage [V] 26.5...31.6 DC; "supply class 2" to cULus. Bus system AS-Interface Product characteristics AS-i Safety at Work AS-i flat cable connection Sockets M12 x 1 Safe AS-i input module 4SI / 2DO T / 2LO Addressing socket Three orientations of the flat cable are possible Complies with the requirements: EN ISO 13849-1: PL d IEC 62061: SILcl 2 Electrical data Electrical design 2x2 safe inputs / 2 non-safe LED outputs / 2 non-safe outputs Operating voltage [V] 26.5...31.6 DC; "supply class 2" to cULus. Current consumption [mA] < 280 Max. current load per module [mA] 200 Inputs Digital Circuit DC PNP Sensor supply AS-i Max. current load for all inputs total [mA] 200 Input current [mA] 8 Short-circuit detection yes Cross-bridging detection no Short-circuit proof yes Outputs Voltage range [V] 24 DC (18...30 DC) LED output 2 LED output / supply via AS-i ja External voltage supply AS-i Signal outputs 2 Max. current load per output [mA] 50 Electrically separated no Integrated watchdog yes Short-circuit proof yes Environment Ambient temperature [°C] -25...55, -25...40 °C with switched outputs Protection IP 67 Tests / approvals EMC EN 50295 EN 62061 annex E Safety classification Mission time TM [h] 175200, (20 years) Safety-related reliability PFHd [1/h] 4.7 E-12 PFH 2.4 x 10E-11 / h MTTFd [Years] 5400 DC/CCF/Cat. 97/-/3 AS-i classification Extended addressing mode possible version 2.11 and 3.0 / no Max. number of safety modules per master 31 AS-i profile S-7.B.E I/O configuration [hex] 7 ID code [Hex] B.E AS-i certificate 97201 Mechanical data Cable length between module and mechanical contacts < 10 m Housing materials PA; Piercing contacts: CuSn6 surface nickel and tin-plated Weight [kg] 0.204 Displays / operating elements Operation LED green Error LED Red Function display LED yellow Electrical connection Max. cable length [m] < 10
»
AS-Interface - AC001S : 0 VND (AC001S )
» AS-Interface - AC002S: 0 VND (AC002S) » AS-Interface - AC003S: 0 VND (AC003S) » AS-Interface - AC004S: 0 VND (AC004S) » AS-Interface - AC031S: 0 VND (AC031S) » AS-Interface - AC032S: 0 VND (AC032S) » AS-Interface - AC041S: 0 VND (AC041S ) |
Tel: (08) - 6675.2925 (08) - 3511.5746 Fax: (08) - 3511.7931 Hot Line: 0978.996.122
|
TRUONG THANH INDUSTRIAL CO., LTD.
29-31 Dinh Bo Linh Street, Ward 24, Binh Thanh District.
Telephone: 08-6675.2925 Fax: 08-3511.7931
Email: kd2@cntruongthanh.com
Hotline: 0978.996.122
29-31 Dinh Bo Linh Street, Ward 24, Binh Thanh District.
Telephone: 08-6675.2925 Fax: 08-3511.7931
Email: kd2@cntruongthanh.com
Hotline: 0978.996.122
Copyright © 2010 cntruongthanh.com
Phát triển bởi N N H